SER
Service Entrance Style R (SER) 600V - 8000 Series Aluminum Alloy
Compact stranded 8000 series aluminum alloy conductors. XHHW-2 insulation on individual conductors. Three conductors with a ground: two insulated conductors with an insulated neutral and bare ground. Gray PVC jacket is extruded over the assembly.
Standards & Specifications
- UL 44 for Type XHHW-2 Conductors
- UL 854
- Federal Specification JC-30B NEC
- 8000 Series AL Alloy
- Flame Retardant Jacket
- Sunlight Resistant Jacket
Scroll to see product information
Wire Size & Specs
Conductor | Ground Conductor | ||||||
---|---|---|---|---|---|---|---|
Size (AWG) | Stranding | Stranding | No. of Conductors | Nom Cable OD | Ampacity* 90° C | Amp Dwelling | Approx Net WT./MFT |
Conductor Size (AWG) 8/3c-8g |
Stranding 7 | Ground Conductor Stranding 7 | No. of Conductors 3 | Nom Cable OD 0.592 |
Ampacity* 90° C 45 |
Amp Dwelling N/A |
Approx Net WT./MFT 130 |
Conductor Size (AWG) 6/3c-6g |
Stranding 7 | Ground Conductor Stranding 7 | No. of Conductors 3 | Nom Cable OD 0.697 |
Ampacity* 90° C 60 |
Amp Dwelling N/A |
Approx Net WT./MFT 185 |
Conductor Size (AWG) 4/3c-6g |
Stranding 7 | Ground Conductor Stranding 7 | No. of Conductors 3 | Nom Cable OD 0.791 |
Ampacity* 90° C 75 |
Amp Dwelling N/A |
Approx Net WT./MFT 246 |
Conductor Size (AWG) 2/3c-4g |
Stranding 7 | Ground Conductor Stranding 7 | No. of Conductors 3 | Nom Cable OD 0.918 |
Ampacity* 90° C 100 |
Amp Dwelling 100 |
Approx Net WT./MFT 351 |
Conductor Size (AWG) 2/4c-4g |
Stranding 7 | Ground Conductor Stranding 7 | No. of Conductors 4 | Nom Cable OD 1.031 |
Ampacity* 90° C 100 |
Amp Dwelling 100 |
Approx Net WT./MFT 453 |
Conductor Size (AWG) 1/3c-3g |
Stranding 19 | Ground Conductor Stranding 7 | No. of Conductors 3 | Nom Cable OD 1.039 |
Ampacity* 90° C 115 |
Amp Dwelling 110 |
Approx Net WT./MFT 443 |
Conductor Size (AWG) 1/0-3c-2g |
Stranding 19 | Ground Conductor Stranding 7 | No. of Conductors 3 | Nom Cable OD 1.143 |
Ampacity* 90° C 135 |
Amp Dwelling 125 |
Approx Net WT./MFT 530 |
Conductor Size (AWG) 2/0-3c-1g |
Stranding 19 | Ground Conductor Stranding 19 | No. of Conductors 3 | Nom Cable OD 1.247 |
Ampacity* 90° C 150 |
Amp Dwelling 150 |
Approx Net WT./MFT 642 |
Conductor Size (AWG) 2/0-4c-1g |
Stranding 19 | Ground Conductor Stranding 19 | No. of Conductors 4 | Nom Cable OD 1.374 |
Ampacity* 90° C 150 |
Amp Dwelling 150 |
Approx Net WT./MFT 827 |
Conductor Size (AWG) 3/0-3c-1/0g |
Stranding 19 | Ground Conductor Stranding 19 | No. of Conductors 3 | Nom Cable OD 1.338 |
Ampacity* 90° C 175 |
Amp Dwelling 175 |
Approx Net WT./MFT 780 |
Conductor Size (AWG) 4/0-3c-2/0g |
Stranding 19 | Ground Conductor Stranding 19 | No. of Conductors 3 | Nom Cable OD 1.472 |
Ampacity* 90° C 205 |
Amp Dwelling 200 |
Approx Net WT./MFT 952 |
Conductor Size (AWG) 4/0-4c-2/0g |
Stranding 19 | Ground Conductor Stranding 19 | No. of Conductors 4 | Nom Cable OD 1.634 |
Ampacity* 90° C 205 |
Amp Dwelling 200 |
Approx Net WT./MFT 1231 |
Conductor Size (AWG) 250/3c-3/0g |
Stranding 37 | Ground Conductor Stranding 19 | No. of Conductors 3 | Nom Cable OD 1.635 |
Ampacity* 90° C 230 |
Amp Dwelling 225 |
Approx Net WT./MFT 1109 |
Conductor Size (AWG) 250/4c-3/0g |
Stranding 37 | Ground Conductor Stranding 19 | No. of Conductors 4 | Nom Cable OD 1.961 |
Ampacity* 90° C 230 |
Amp Dwelling 225 |
Approx Net WT./MFT 1458 |
*Allowable ampacity shown above is per National Electrical Code. The above data is approximate and subject to normal manufacturing tolerances. |