DOWNLOAD PRODUCT SPECSView Tech DocumentsEmail Specs
Enter your name and email, and we will email your specs.
UD Cable – Triplex
UD Cable Triplex - Secondary Aluminum - 600V
Product may be buried directly in the ground or installed in ducts for 600 volt secondary applications. Product is comprised of concentric stranded or compressed 1350-H19 aluminum conductor with XLP insulation. Neutral conductors to be identified with a yellow stripe.
Standards & Specifications
- ASTM B-230
- ATSM B-231
- ICEA S-105692
- UL 854 for type USE-2
- Direct Burial Rated
- Sunlight Resistant
- Federal Specification JC-308 NEC
- 600V Rated
Scroll to see product information
Wire Size & Specs
600V Secondary AL UD Cable – Triplex | |||||||||
---|---|---|---|---|---|---|---|---|---|
Part # | Phase Conductor (AWG) |
Phase Conductor Stranding |
Phase Conductor Insul. Thick.Mils |
Neutral (AWG) |
Neutral Stranding |
Neutral Insul. Thick.Mils |
Cable OD Single Phase (Inches) |
Cable OD Complete Cable (Inches) |
Lbs./M' |
Part # Erksine |
Phase Conductor(AWG) 6 |
Phase Conductor Stranding 7 |
Phase Conductor Insul.Thick.Mils 0.060 |
Neutral AWG 6 |
Neutral Stranding 7 |
Neutral Insul.Thick.Mils 0.060 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 0.660 |
Lbs./M 133 |
Part # Vassar |
Phase Conductor(AWG) 4 |
Phase Conductor Stranding 7 |
Phase Conductor Insul.Thick.Mils 0.060 |
Neutral AWG 4 |
Neutral Stranding 7 |
Neutral Insul.Thick.Mils 0.060 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 0.760 |
Lbs./M 188 |
Part # Ramapo |
Phase Conductor(AWG) 2 |
Phase Conductor Stranding 7 |
Phase Conductor Insul.Thick.Mils 0.060 |
Neutral AWG 2 |
Neutral Stranding 7 |
Neutral Insul.Thick.Mils 0.060 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 0.880 |
Lbs./M 272 |
Part # Stephens |
Phase Conductor(AWG) 2 |
Phase Conductor Stranding 7 |
Phase Conductor Insul.Thick.Mils 0.060 |
Neutral AWG 4 |
Neutral Stranding 7 |
Neutral Insul.Thick.Mils 0.060 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 0.880 |
Lbs./M 243 |
Part # Brenau |
Phase Conductor(AWG) 1/0 |
Phase Conductor Stranding 19 |
Phase Conductor Insul.Thick.Mils 0.080 |
Neutral AWG 2 |
Neutral Stranding 7 |
Neutral Insul.Thick.Mils 0.060 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.100 |
Lbs./M 385 |
Part # Bergen |
Phase Conductor(AWG) 1/0 |
Phase Conductor Stranding 19 |
Phase Conductor Insul.Thick.Mils 0.080 |
Neutral AWG 1/0 |
Neutral Stranding 19 |
Neutral Insul.Thick.Mils 0.080 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.140 |
Lbs./M 460 |
Part # Hunter |
Phase Conductor(AWG) 2/0 |
Phase Conductor Stranding 19 |
Phase Conductor Insul.Thick.Mils 0.080 |
Neutral AWG 2/0 |
Neutral Stranding 19 |
Neutral Insul.Thick.Mils 0.080 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.240 |
Lbs./M 558 |
Part # Converse |
Phase Conductor(AWG) 2/0 |
Phase Conductor Stranding 19 |
Phase Conductor Insul.Thick.Mils 0.080 |
Neutral AWG 1 |
Neutral Stranding 19 |
Neutral Insul.Thick.Mils 0.080 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.190 |
Lbs./M 480 |
Part # Sweetbriar |
Phase Conductor(AWG) 4/0 |
Phase Conductor Stranding 19 |
Phase Conductor Insul.Thick.Mils 0.080 |
Neutral AWG 2/0 |
Neutral Stranding 19 |
Neutral Insul.Thick.Mils 0.080 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.410 |
Lbs./M 706 |
Part # Monmouth |
Phase Conductor(AWG) 4/0 |
Phase Conductor Stranding 19 |
Phase Conductor Insul.Thick.Mils 0.080 |
Neutral AWG 4/0 |
Neutral Stranding 19 |
Neutral Insul.Thick.Mils 0.080 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.470 |
Lbs./M 828 |
Part # Pratt |
Phase Conductor(AWG) 250 |
Phase Conductor Stranding 37 |
Phase Conductor Insul.Thick.Mils 0.095 |
Neutral AWG 3/0 |
Neutral Stranding 19 |
Neutral Insul.Thick.Mils 0.080 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.630 |
Lbs./M 862 |
Part # Wesleyan |
Phase Conductor(AWG) 350 |
Phase Conductor Stranding 37 |
Phase Conductor Insul.Thick.Mils 0.095 |
Neutral AWG 4/0 |
Neutral Stranding 19 |
Neutral Insul.Thick.Mils 0.080 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 1.790 |
Lbs./M 1123 |
Part # Rider |
Phase Conductor(AWG) 500 |
Phase Conductor Stranding 37 |
Phase Conductor Insul.Thick.Mils 0.095 |
Neutral AWG 350 |
Neutral Stranding 37 |
Neutral Insul.Thick.Mils 0.095 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 2.050 |
Lbs./M 1607 |
Part # Fairfield |
Phase Conductor(AWG) 750 |
Phase Conductor Stranding 61 |
Phase Conductor Insul.Thick.Mils 0.110 |
Neutral AWG 500 |
Neutral Stranding 61 |
Neutral Insul.Thick.Mils 0.095 |
Cable OD Single Cable (Inches) |
Cable OD Complete Cable (Inches) 2.580 |
Lbs./M 2379 |
Customer Support & Order Information
At Alan Wire, we’re proudly committed to serving you. Find the help you need or access your order information by making a selection below.
FREIGHT PRE-PAID
Orders Over 2,000 Pounds
Our low freight pre-paid threshold makes our products more affordable and accessible to everyone, not just the largest of customers.